KEM

Titrators & Density Meters



KEM
Measuring method: Resonant frequency oscillation
Density accuracy: ±2x10-5g/cm3
Temperature accuracy: ±0.02°C

KEM offers a wide range of density meters / specific gravity meters, which belong to the most accurate density meters in the world. Quickest measurements are completed in 20 seconds and minimum sample size is 1ml. The measuring parameters include density, temp-compensated density, SG, temp-compensated SG, Brix%, alcohol concentration, sulfuric acid concentration, API degree, Baume degree, Plato degree, Proof degree, and more.

Important features the viscosity correction for high-viscosity samples and the portable density meter model DA-130N. More info

KEM
+ Density meter
+ Refractometer
+ Gondola-transfer sampler
= All-in-one Analyzer

KEM’s all-in-one analyzer ASCA-6400 presents a new concept of analysis, consisting of high-precision density meter / specific gravity meter, refractometer and newly-designed Gondola-transfer sampler in one instrument. It can simultaneously handle up to 48 samples (in 20ml vials), guarantees high-precision measurements, and perfectly fits fragrance, brewing and beverage makers who need to test a lot of samples every day. More info

KEM
Detection range
Potentiometric:-2'000mV to +2'000mV
pH: -20'000 to 20'000pH
Temperature: 0 to 100°C

The AT-710B was developed for potentiometric (acid/base, redox, precipitation), photometric, polarization and conductivity titration. It is equipped with a black-white interface which can store up to 50 samples. Connection to a computer, dot matrix printer and electronic balance is possible through USB or LAN.

The system can control up to 10 automatic piston burette drives and is compatible with the CHA-700 multiple sample changer. More info

KEM
The MKV-710B for volumetric titrations has a measuring range of 0.1 to 500mgH2O (water content) and 10ppm to 100%H2O (concentration). It can control up to 2 automatic piston burette drives for normal and back titration. The polarized potential level detection works with a twin platinum electrode.

The MKC-710B for coulometric titrations has a measuring range of 10µg to 300mg (water content/Bromine index) due to its 2-component or 1-component measurement cell. Different evaporators / ovens to measure the moisture content in powders and solid samples are available.

Both models are equipped with a black-white interface which can store up to 100 samples and 20 methods. Connection to a computer, dot matrix printer and electronic balance is possible through USB or LAN. More info

KEM
Detection range
Potentiometric:-2'000mV to +2'000mV
pH: -20'000 to 20'000pH
Temperature: 0 to 100°C

The AT-710S was developed for potentiometric (acid/base, redox, precipitation), photometric, polarization and conductivity titration. It is equipped with a large color interface which can store up to 500 samples. It can easily be upgraded to the high-end model AT-710M. Connection to a computer, dot matrix printer and electronic balance is possible through USB or LAN.

The system can control up to 10 automatic piston burette drives and is compatible with the CHA-600 and CHA-700 multiple sample changer. More info

KEM
The MKV-710S for volumetric titrations has a measuring range of 0.1 to 500mgH2O (water content) and 10ppm to 100%H2O (concentration). It can control up to 2 automatic piston burette drives for normal and back titration. The polarized potential level detection works with a twin platinum electrode.

The MKC-710S for coulometric titrations has a measuring range of 10µg to 300mg (water content/Bromine index) due to its 2-component or 1-component measurement cell. Different evaporators / ovens to measure the moisture content in powders and solid samples are available.

Both models are equipped with a large color interface which can store up to 500 samples and 120 methods. Connection to a computer, dot matrix printer and electronic balance is possible through USB or LAN. More info

KEM
Detection range
Potentiometric:-2'000mV to +2'000mV
pH: -20'000 to 20'000pH
Temperature: 0 to 100°C

The AT-710M was developed for potentiometric (acid/base, redox, precipitation), photometric, polarization and conductivity titration. It is equipped with a large color interface which can display up to 4 channels simultaneously and store up to 500 samples. For simultaneous titrations, it can be connected with up to 4 titrators, including other potentiometric titrators or Karl Fischer moisture titrators. Connection to a computer, dot matrix printer and electronic balance is possible through USB or LAN.

The system can control up to 10 automatic piston burette drives and is compatible with the CHA-600 and CHA-700 multiple sample changer. More info

KEM
The MKV-710M for volumetric titrations has a measuring range of 0.1 to 500mgH2O (water content) and 10ppm to 100%H2O (concentration). It can control up to 2 automatic piston burette drives for normal and back titration. The polarized potential level detection works with a twin platinum electrode.

The MKC-710M for coulometric titrations has a measuring range of 10µg to 300mg (water content/Bromine index) due to its 2-component or 1-component measurement cell. Different evaporators / ovens to measure the moisture content in powders and solid samples are available.

Both models are equipped with a large color interface which can display up to 4 channels simultaneously and store up to 500 samples and 120 methods. For simultaneous titrations, it can be connected with up to 4 titrators, including potentiometric titrators or other Karl Fischer moisture titrators. Connection to a computer, dot matrix printer and electronic balance is possible through USB or LAN. More info

KEM
The CHA-700 multiple sample changer with 6 or 11 positions for samples performs titration automatically. The arm moves to a sample container and the table lifts up to perform titration. The titrator can be mounted directly to the sample changer. Container sizes range from 50 ml to 250 ml.

Compatible with AT-710M / AT-710S / AT-710B More info

KEM
The Hybrid Karl Fischer Moisture Titrator MKH-700 is one of the world's first systems for the hybrid titration method which uses volumetric titration method, coulometric titration method and Electrolytic Factor Measurement which does not require pure water for factor determination. The hybrid titration method automatically switches between the parallel measurement under volumetric and coulometric method by monitoring the moisture content in the titration cell and delivers good results even if the water content of the sample is high. More info

KEM
The CHA-600 multiple sample changer with 12 or 18 positions for samples performs preheatment, titration, and electrode cleaning automatically and can handle titration of both aqueous and non-aqueous samples. Container sizes range from 50 ml to 300 ml.

Compatible with AT-710M / AT-710S More info